Ürünler

Sensör Pepperl+Fuchs
Endüktif Sensör Pepperl Fuchs NBN30-U4-E0
Sensör Pepperl+Fuchs
Endüktif Sensör Pepperl Fuchs NBN30-U4-E2-V1
Tümünü Göster

Endüktif Sensör Pepperl Fuchs NBN30-U4-E2

Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBN30-U4-E2
Pepperl NBN30-U4-E2
NBN30-U4-E2

Açıklama

Pepperl Fuchs NBN30-U4-E2 Endüktif Sensör
Pepperl NBN30-U4-E2 Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBN30-U4-E2
Pepperl Fuchs NBN30-U4-E2 Yakınlık Sensörü
Inductive Sensor NBN30-U4-E2 Pepperl-Fuchs
Endüktif Sensör NBN30-U4-E2 Pepperl-Fuchs

Teknik veriler NBN30-U4-E2

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance30 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 … 24.3 mm
Actual operating distance27 … 33 mm typ. 30 mm
Reduction factor rAl0.33
Reduction factor rCu0.31
Reduction factor r3040.74
Reduction factor rBrass0.38
Output type3-wire
Nominal ratings
Operating voltage10 … 30 V
Switching frequency0 … 230 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2 V
Operating current0 … 200 mA
Off-state current0 … 0.5 mA typ. 0.01 mA
No-load supply current≤ 20 mA
Time delay before availability80 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1510 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 … 85 °C (-13 … 185 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPA/metal with epoxy powder coating
Sensing facePA
Housing basemetal
Degree of protectionIP68 / IP69K
Mass225 g
NoteTightening torque: 1.8 Nm (housing)