Ürünler

Ultrasonic Sensor Pepperl Fuchs
Endüktif Sensör Pepperl Fuchs NBN40-L2-A2-V1
Pepperl Fuchs Ultrasonic Sensor
Endüktif Sensör Pepperl Fuchs NBN5-11K8-N-V8
Tümünü Göster

Endüktif Sensör Pepperl Fuchs NBN40-L2-A2-V1-3G-3D

Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NBN40-L2-A2-V1-3G-3D
Pepperl NBN40-L2-A2-V1-3G-3D
NBN40-L2-A2-V1-3G-3D

Açıklama

Pepperl Fuchs NBN40-L2-A2-V1-3G-3D Endüktif Sensör
Pepperl NBN40-L2-A2-V1-3G-3D Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NBN40-L2-A2-V1-3G-3D
Pepperl Fuchs NBN40-L2-A2-V1-3G-3D Yakınlık Sensörü
Inductive Sensor NBN40-L2-A2-V1-3G-3D Pepperl-Fuchs
Endüktif Sensör NBN40-L2-A2-V1-3G-3D Pepperl-Fuchs

Teknik veriler NBN40-L2-A2-V1-3G-3D

General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance40 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 … 32.4 mm
Actual operating distance36 … 44 mm
Reduction factor rAl0.31
Reduction factor rCu0.3
Reduction factor r3040.74
Reduction factor rBrass0.39
Output type4-wire
Nominal ratings
Operating voltage10 … 30 V DC
Switching frequency0 … 180 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2 V
Operating current0 … 200 mA
Off-state current0 … 0.5 mA
No-load supply current≤ 20 mA
Time delay before availability80 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1057 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection classII
Rated insulation voltage253 V
Rated impulse withstand voltage4000 V
UL approvalcULus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 … 85 °C (-13 … 185 °F)
Storage temperature-40 … 85 °C (-40 … 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialPA
Sensing facePA
Degree of protectionIP69K
Mass130 g
Data for application in connection with hazardous areas
Equipment protection levelGc (nA) , Dc
Equipment protection level Gc (nA)
Type of protection“n”
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3754X
ATEX markingII 3G Ex nA IIC T6 Gc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-15:2010
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F)
at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F)
at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F)
at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F)
Equipment protection level Dc
Type of protectionProtection by enclosure “tc”
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3774X
ATEX markingII 3D Ex tc IIIC T80°C Dc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-31:2014
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F)
at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F)
at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F)
at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F)
General information
Use in the hazardous areasee instruction manuals
Top