Sensör Pepperl+Fuchs
Endüktif Sensör Pepperl Fuchs NJ2,5-14GM-N-V1-Y21146
Sensör Pepperl Fuchs
Endüktif Sensör Pepperl Fuchs NJ2-11-N-G
Tümünü Göster

Endüktif Sensör Pepperl Fuchs NJ2-11-N

Sensör
Yakınlık Sensörü
Proximity Sensor
Endüktif Proximity Sensör
Inductive Proximity Sensor
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Proximity Sensor
Pepperl Fuchs Yakınlık Sensörü
Pepperl Fuchs Endüktif Proximity Sensör
Pepperl Fuchs Inductive Proximity Sensor
Pepperl Fuchs NJ2-11-N
Pepperl NJ2-11-N
NJ2-11-N

Açıklama

Pepperl Fuchs NJ2-11-N Endüktif Sensör
Pepperl NJ2-11-N Inductive Sensor
Yaklaşım Sensörü Pepperl Fuchs NJ2-11-N
Pepperl Fuchs NJ2-11-N Yakınlık Sensörü
Inductive Sensor NJ2-11-N Pepperl-Fuchs
Endüktif Sensör NJ2-11-N Pepperl-Fuchs

Teknik veriler NJ2-11-N

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 … 1.62 mm
Actual operating distance1.8 … 2.2 mm
Reduction factor rAl0.4
Reduction factor rCu0.3
Reduction factor r3040.85
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 … 3000 Hz
Hysteresis0.5 … 3.5 typ. 2 %
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
MTTFd5887 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Approvals and certificates
FM approval
Control drawing116-0165
UL approvalcULus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 … 100 °C (-13 … 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialPVDF
Sensing facePVDF
Degree of protectionIP68
Cable
Bending radius> 10 x cable diameter
Data for application in connection with hazardous areas
Equipment protection levelGa , Gb , Gc (ic) , Da , Mb
General information
Use in the hazardous areasee instruction manuals
Top