Ürünler

Pepperl Ultrasonik Sensörler
Karşılıklı Tip Fotoelektrik Sensör Pepperl Fuchs LA39/LK39-Z/31/40a/116
Pepperl Fuchs Ultrasonic Sensor
Karşılıklı Tip Fotoelektrik Sensör Pepperl Fuchs LA61/LK61-Z/31/115
Tümünü Göster

Karşılıklı Tip Fotoelektrik Sensör Pepperl Fuchs LA39/LK39/31/40a/116

Sensör
Fotoelektrik Sensör
Thru-beam Sensor
Karşılıklı Tip Fotoelektrik Sensör
Pepperl Fuchs
Pepperl Fuchs Sensör
Pepperl Fuchs Fotoelektrik Sensör
Pepperl Fuchs Thru-beam Sensor
Pepperl Fuchs Karşılıklı Tip Fotoelektrik Sensör
Pepperl Fuchs LA39/LK39/31/40a/116
Pepperl LA39/LK39/31/40a/116
LA39/LK39/31/40a/116

Açıklama

Pepperl Fuchs LA39/LK39/31/40a/116 Karşılıklı Tip Fotoelektrik Sensör
Pepperl LA39/LK39/31/40a/116 Thru-beam Sensor
Fotoelektrik Sensör Pepperl Fuchs LA39/LK39/31/40a/116
Pepperl Fuchs LA39/LK39/31/40a/116 Fotoelektrik Sensör
Thru-beam Sensor LA39/LK39/31/40a/116 Pepperl-Fuchs
Karşılıklı Tip Fotoelektrik Sensör LA39/LK39/31/40a/116 Pepperl-Fuchs

Teknik veriler LA39/LK39/31/40a/116

Ürün Açıklaması
Thru-beam sensor, 20 m detection range, infrared light, light/dark on, AC/DC version, relay contact output, sensitivity adjuster, terminal compartment

 

System components
EmitterLA39/116
ReceiverLK39/31/40a/116
General specifications
Effective detection range0 … 20 m
Threshold detection range25 m
Adjustment range2 … 25 m
Reference targetreceiver
Light sourceIRED
Light typemodulated infrared light
Ambient light limitIEC / EN 60947-5-2 , 10000 Lux
Functional safety related parameters
MTTFd916 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED red (emitter)
Function indicatorLED yellow: switching state
LED red: pre-fault indication
Control elementsSensing range adjuster, light-on/dark-on changeover switch
Electrical specifications
Operating voltage12 … 240 V DC / 24 … 240 V AC (50 … 60 Hz)
Ripple10 %
No-load supply current≤ 60 mA receiver and emitter
Protection classII, rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution!
The protection class 2 is only valid when the terminal compartment is closed. output circuit has basic insulation to control circuit according to IEC/EN 61140
Power consumption≤ 3 VA
Time delay before availability≤ 300 ms
Output
Switching typelight/dark on
Signal output1 relay output
Switching voltagemax. 240 V AC ; 150 V DC
Switching currentmax. 3 A
Switching powerDC: max. 90 W AC: max. 750 VA
Switching frequency≤ 25 Hz
Response time≤ 20 ms
Compliance with standards and directives
Directive conformityEMC Directive 2004/108/EC
EMC Directive 2004/108/ECEN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007+A1:2012
Standard conformity
Product standardEN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
EAC conformityTR CU 020/2011
TR CU 004/2011
CCC approvalCertified by China Compulsory Certification (CCC)
ApprovalsCE
Ambient conditions
Ambient temperature-25 … 55 °C (-13 … 131 °F)
Storage temperature-40 … 70 °C (-40 … 158 °F)
Mechanical specifications
Housing width25 mm
Housing height64 mm
Housing depth75 mm
Degree of protectionIP67
Connectionterminal compartment PG9, ≤ 2.5 mm2
Material
HousingPBT
Optical facePMMA
MassEmitter: approx. 90 g receiver: approx. 110 g
General information
Scope of deliveryMounting aid
Top